cve.bz

CVE-2017-14022 rockwellautomation factorytalk alarms and events: Improper Input Validation

7.5 highEPSS 4.2%

High (7.5) in rockwellautomation factorytalk alarms and events. EPSS 4.2% estimated probability of exploitation activity in the next 30 days.

On this page
An Improper Input Validation issue was discovered in Rockwell Automation FactoryTalk Alarms and Events, Version 2.90 and earlier. An unauthenticated attacker with remote access to a network with FactoryTalk Alarms and Events can send a specially crafted set of packets packet to Port 403/TCP (the history archiver service), causing the service to either stall or terminate.

Severity

CVSS 3.0

7.5 high
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
EPSS
4.2% (unchanged from 4.2% a week ago; 4.2% 30 days ago) estimated probability of exploitation activity in the next 30 days; 91st percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-20 Improper Input Validation
OWASP Top 10
A05:2025 Injection
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2017-14022 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2017-14022?via=ask-ai-copy and https://cve.bz/cve/CVE-2017-14022?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2017-14022 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
rockwellautomation:factorytalk_alarms_and_eventsthrough 2.90

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-17-341-02Rockwell Automation FactoryTalk Alarms and Events2017-12-07Chemical, Critical Manufacturing, Food and Agriculture, Water and Wastewater SystemsFactoryTalk Services (RSLinx Enterprise): all versions, FactoryTalk View SE: versions 5.00 and later, FactoryTalk Alarms and Events: Version 2.90 and earlier and 1 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.