cve.bz

CVE-2016-8354 schneider-electric unity pro: Code Injection

7.0 highEPSS 1.1%

High (7.0) in schneider-electric unity pro. EPSS 1.1% estimated probability of exploitation activity in the next 30 days.

On this page
An issue was discovered in Schneider Electric Unity PRO prior to V11.1. Unity projects can be compiled as x86 instructions and loaded onto the PLC Simulator delivered with Unity PRO. These x86 instructions are subsequently executed directly by the simulator. A specially crafted patched Unity project file can make the simulator execute malicious code by redirecting the control flow of these instructions.

Severity

CVSS 3.0

7.0 high
CVSS:3.0/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H
EPSS
1.1% (unchanged from 1.1% a week ago; 1.1% 30 days ago) estimated probability of exploitation activity in the next 30 days; 67th percentile. Scored 2026-11-21. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-94 Improper Control of Generation of Code (Code Injection)
OWASP Top 10
A05:2025 Injection
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2016-8354 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2016-8354?via=ask-ai-copy and https://cve.bz/cve/CVE-2016-8354?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2016-8354 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
schneider-electric:unity_prothrough 11.0

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-16-306-03Schneider Electric Unity PRO Control Flow Management Vulnerability2016-08-05Schneider Electric Unity PRO: <V11.1none listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-35 Leverage Executable Code in Non-Executable Files Likelihood: High · Severity: Very High
  • CAPEC-77 Manipulating User-Controlled Variables Likelihood: High · Severity: Very High
  • CAPEC-242 Code Injection Likelihood: High · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON