cve.bz

CVE-2015-6462 schneider-electric: Cross-site Scripting

5.4 mediumEPSS 0.6%

Medium (5.4) in schneider-electric. EPSS 0.6% estimated probability of exploitation activity in the next 30 days.

On this page
Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser.

Severity

CVSS 3.0

5.4 medium
CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
EPSS
0.6% (unchanged from 0.6% a week ago; 0.6% 30 days ago) estimated probability of exploitation activity in the next 30 days; 47th percentile. Scored 2026-11-21. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting)
OWASP Top 10
A05:2025 Injection
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2015-6462 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2015-6462?via=ask-ai-copy and https://cve.bz/cve/CVE-2015-6462?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2015-6462 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-15-246-02Schneider Electric Modicon PLC Vulnerabilities2015-06-06Schneider Electric Modicon PLC: BMXNOC0401, Schneider Electric Modicon PLC: BMXNOE0100, Schneider Electric Modicon PLC: BMXNOE0110 and 8 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-63 Cross-Site Scripting (XSS) Likelihood: High · Severity: Very High
  • CAPEC-85 AJAX Footprinting Likelihood: High · Severity: Low
  • CAPEC-209 XSS Using MIME Type Mismatch Severity: Medium
  • CAPEC-588 DOM-Based XSS Likelihood: High · Severity: Very High
  • CAPEC-591 Reflected XSS Likelihood: High · Severity: Very High
  • CAPEC-592 Stored XSS Likelihood: High · Severity: Very High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON