cve.bz

CVE-2014-9197 schneider-electric: Improper Access Control

no score yetEPSS 2.0%Fix available

schneider-electric: no CVSS score yet. EPSS 2.0% estimated probability of exploitation activity in the next 30 days.

On this page
The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request.
EPSS
2.0% (unchanged from 2.0% a week ago; 2.0% 30 days ago) estimated probability of exploitation activity in the next 30 days; 81st percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWEs
CWE-306 Missing Authentication for Critical Functionality
CWE-284 Improper Access Control
OWASP Top 10
A01:2025 Broken Access Control, A07:2025 Authentication Failures
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2014-9197 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2014-9197?via=ask-ai-copy and https://cve.bz/cve/CVE-2014-9197?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2014-9197 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
schneider-electric:etg3000_factorycast_hmi_gateway_firmware1.60.2

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-15-020-02Schneider Electric ETG3000 FactoryCast HMI Gateway Vulnerabilities2015-10-23Schneider Electric TSXETG3000: vers:all/*, Schneider Electric TSXETG3010: vers:all/*, Schneider Electric TSXETG3021: vers:all/* and 1 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-12 Choosing Message Identifier Likelihood: High · Severity: High
  • CAPEC-36 Using Unpublished Interfaces or Functionality Likelihood: Medium · Severity: High
  • CAPEC-62 Cross Site Request Forgery Likelihood: High · Severity: Very High
  • CAPEC-166 Force the System to Reset Values Severity: Medium
  • CAPEC-216 Communication Channel Manipulation

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits. More on the page of CWE-284 (17).

References

Check your stackJSON