The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets.
EPSS
2.0% (unchanged from 2.0% a week ago; 2.0% 30 days ago) estimated probability of exploitation activity in the next 30 days; 82nd percentile. Scored 2026-11-21. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-200 Exposure of Sensitive Information to an Unauthorized Actor
OWASP Top 10
A01:2025 Broken Access Control
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2014-8552 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2014-8552?via=ask-ai-copy and https://cve.bz/cve/CVE-2014-8552?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2014-8552 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
siemens:simatic_pcs_77.1:sp1
siemens:simatic_pcs77.1:sp3
siemens:simatic_pcs77.1:sp4
siemens:simatic_pcs78.0:sp1
siemens:simatic_pcs78.0:sp2
siemens:simatic_pcs78.1
siemens:simatic_tiaportal13.0
siemens:simatic_tiaportal13.0:3
siemens:simatic_tiaportal13.0:5
siemens:simatic_wincc7.0
siemens:simatic_wincc7.0:sp1
siemens:simatic_wincc7.0:sp2
siemens:simatic_wincc7.0:sp3
siemens:simatic_wincc7.2:1
siemens:simatic_wincc7.2:2
siemens:simatic_wincc7.2:3
siemens:simatic_wincc7.2:4
siemens:simatic_wincc7.2:5
siemens:simatic_wincc7.2:6
siemens:simatic_wincc7.2:7
siemens:simatic_wincc7.2:8
siemens:simatic_wincc7.3:1

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-14-329-02DSiemens SIMATIC WinCC, PCS7, and TIA Portal Vulnerabilities2014-08-28Siemens SIMATIC WinCC V7.0 SP3 and prior: vers:all/*, Siemens SIMATIC WinCC V7.2: <V7.2_Update_9, Siemens SIMATIC WinCC V7.3: <V7.3_Update_2 and 4 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits. More on the page of CWE-200 (59).

References

Check your stackJSON