CVE-2014-5411 Cross-site Scripting
No CVSS score yet. EPSS 1.3% estimated probability of exploitation activity in the next 30 days.
On this page
Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allow remote authenticated users to inject arbitrary web script or HTML via unspecified vectors.
- EPSS
- 1.3% (unchanged from 1.3% a week ago; 1.3% 30 days ago) estimated probability of exploitation activity in the next 30 days; 71st percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
- CWE
- CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting)
- OWASP Top 10
- A05:2025 Injection
- Published
- Modified
- NVD analysis
- Analyzed, since modified
- Record from
- the NVD, synced
Ask an AI about this CVE
Show the prompt
Explain CVE-2014-5411 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2014-5411?via=ask-ai-copy and https://cve.bz/cve/CVE-2014-5411?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2014-5411 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.
Affected
Versions
From the NVD's CPE matches.
| Product | Affected |
|---|---|
| aveva:clearscada | 2010:r3 |
| aveva:clearscada | 2010:r3.1 |
| aveva:clearscada | 2013:r1 |
| aveva:clearscada | 2013:r1.1 |
| aveva:clearscada | 2013:r1.1a |
| aveva:clearscada | 2013:r1.2 |
| aveva:clearscada | 2013:r2 |
| schneider-electric:scada_expert_clearscada | 2013:r2.1 |
| schneider-electric:scada_expert_clearscada | 2014:r1 |
ICS advisories (CISA)
| Advisory | Title | Published | Sectors | Affected | Fixed |
|---|---|---|---|---|---|
| ICSA-14-259-01A | Schneider Electric SCADA Expert ClearSCADA Vulnerabilities (Update A) | 2014-06-19 | Schneider Electric ClearSCADA 2010: R3_build_72.4560, Schneider Electric ClearSCADA 2010: R3.1_build_72.4644, Schneider Electric SCADA Expert ClearSCADA 2013: R1_build_73.4729 and 6 more | none listed |
From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.
Attack patterns (CAPEC)
- CAPEC-63 Cross-Site Scripting (XSS) Likelihood: High · Severity: Very High
- CAPEC-85 AJAX Footprinting Likelihood: High · Severity: Low
- CAPEC-209 XSS Using MIME Type Mismatch Severity: Medium
- CAPEC-588 DOM-Based XSS Likelihood: High · Severity: Very High
- CAPEC-591 Reflected XSS Likelihood: High · Severity: Very High
- CAPEC-592 Stored XSS Likelihood: High · Severity: Very High
The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.