CVE-2014-2375 ecava integraxor: External Control of File Name or Path
ecava integraxor: no CVSS score yet. EPSS 2.3% estimated probability of exploitation activity in the next 30 days.
On this page
Ecava IntegraXor SCADA Server Stable 4.1.4360 and earlier and Beta 4.1.4392 and earlier allows remote attackers to read or write to arbitrary files, and obtain sensitive information or cause a denial of service (disk consumption), via the CSV export feature.
- EPSS
- 2.3% (unchanged from 2.3% a week ago; 2.3% 30 days ago) estimated probability of exploitation activity in the next 30 days; 84th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
- CWEs
- CWE-73 External Control of File Name or Path
CWE-264 Permissions, Privileges, and Access Controls - OWASP Top 10
- A06:2025 Insecure Design
- Published
- Modified
- NVD analysis
- Analyzed, since modified
- Record from
- the NVD, synced
Fix and patched versions
Ask an AI about this CVE
Show the prompt
Explain CVE-2014-2375 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2014-2375?via=ask-ai-copy and https://cve.bz/cve/CVE-2014-2375?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2014-2375 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.
Affected
Versions
From the CNA's record in the CVE List.
| Product | Affected |
|---|---|
| Ecava IntegraXor SCADA Server | through v4.1.4360 |
| Ecava IntegraXor SCADA Server | through v4.1.4392 |
ICS advisories (CISA)
| Advisory | Title | Published | Sectors | Affected | Fixed |
|---|---|---|---|---|---|
| ICSA-14-224-01 | Ecava Integraxor SCADA Server Vulnerabilities | 2014-05-15 | Ecava IntegraXor SCADA Server: <=v4.1.4360, Ecava IntegraXor SCADA Server: <=v4.1.4392 | none listed |
From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.
Attack patterns (CAPEC)
- CAPEC-13 Subverting Environment Variable Values Likelihood: High · Severity: Very High
- CAPEC-64 Using Slashes and URL Encoding Combined to Bypass Validation Logic Likelihood: High · Severity: High
- CAPEC-72 URL Encoding Likelihood: High · Severity: High
- CAPEC-76 Manipulating Web Input to File System Calls Likelihood: High · Severity: Very High
- CAPEC-78 Using Escaped Slashes in Alternate Encoding Likelihood: High · Severity: High
- CAPEC-79 Using Slashes in Alternate Encoding Likelihood: High · Severity: High
- CAPEC-80 Using UTF-8 Encoding to Bypass Validation Logic Likelihood: High · Severity: High
- CAPEC-267 Leverage Alternate Encoding Likelihood: High · Severity: High
The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.