CVE-2014-0779 aveva clearscada
aveva clearscada: no CVSS score yet. EPSS 1.5% estimated probability of exploitation activity in the next 30 days.
On this page
The PLC driver in ServerMain.exe in the Kepware KepServerEX 4 component in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R2 build 71.4165, 2010 R2.1 build 71.4325, 2010 R3 build 72.4560, 2010 R3.1 build 72.4644, 2013 R1 build 73.4729, 2013 R1.1 build 73.4832, 2013 R1.1a build 73.4903, 2013 R1.2 build 73.4955, and 2013 R2 build 74.5094 allows remote attackers to cause a denial of service (application crash) via a crafted OPF file (aka project file).
- EPSS
- 1.5% (unchanged from 1.5% a week ago; 1.5% 30 days ago) estimated probability of exploitation activity in the next 30 days; 75th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
- CWE
- CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer
- Published
- Modified
- NVD analysis
- Analyzed, since modified
- Record from
- the NVD, synced
Fix and patched versions
Ask an AI about this CVE
Show the prompt
Explain CVE-2014-0779 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2014-0779?via=ask-ai-copy and https://cve.bz/cve/CVE-2014-0779?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2014-0779 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.
Affected
Versions
From the NVD's CPE matches.
| Product | Affected |
|---|---|
| aveva:clearscada | 2010:r2 |
| aveva:clearscada | 2010:r2.1 |
| aveva:clearscada | 2010:r3 |
| aveva:clearscada | 2010:r3.1 |
| aveva:clearscada | 2013:r1 |
| aveva:clearscada | 2013:r1.1 |
| aveva:clearscada | 2013:r1.1a |
| aveva:clearscada | 2013:r1.2 |
| aveva:clearscada | 2013:r2 |
ICS advisories (CISA)
| Advisory | Title | Published | Sectors | Affected | Fixed |
|---|---|---|---|---|---|
| ICSA-14-072-01 | Schneider Electric StruxureWare SCADA Expert ClearSCADA Parsing Vulnerability | 2014-12-14 | Schneider Electric ClearSCADA 2010 R2: Build_71.4165, Schneider Electric ClearSCADA 2010 R2.1: Build_71.4325, Schneider Electric ClearSCADA 2010 R3: Build_72.4560 and 6 more | none listed |
From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.
Attack patterns (CAPEC)
The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits. More on the page of CWE-119 (12).