CVE-2013-3075
No CVSS score yet. EPSS 11% estimated probability of exploitation activity in the next 30 days.
On this page
Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control.
- EPSS
- 11% (unchanged from 11% a week ago; 11% 30 days ago) estimated probability of exploitation activity in the next 30 days; 96th percentile. Scored 2026-11-21. A forecast for this CVE across the internet, not for your own systems.
- CWE
- CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer
- Published
- Modified
- NVD analysis
- Analyzed, since modified
- Record from
- the NVD, synced
Ask an AI about this CVE
Show the prompt
Explain CVE-2013-3075 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2013-3075?via=ask-ai-copy and https://cve.bz/cve/CVE-2013-3075?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2013-3075 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.
Affected
- mitsubishi-automation:mitsubishi_mx_component
- schneider-electric:citectfacilities
- schneider-electric:citectscada
Versions
From the NVD's CPE matches.
| Product | Affected |
|---|---|
| mitsubishi-automation:mitsubishi_mx_component | 3 |
| schneider-electric:citectfacilities | 7.10 |
| schneider-electric:citectscada | 7.10:r1 |
ICS advisories (CISA)
| Advisory | Title | Published | Sectors | Affected | Fixed |
|---|---|---|---|---|---|
| ICSA-13-140-01 | Mitsubishi Electric Automation MX Component V3 ActiveX Vulnerability | 2013-02-21 | Mitsubishi Electric Automation MX Component: 3, Mitsubishi Electric CitectFacilities: <=v7.10, Mitsubishi Electric CitectSCADA: <=v7.0 | none listed |
From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.
Public exploits
Attack patterns (CAPEC)
The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits. More on the page of CWE-119 (12).