CVE-2013-0657 schneider-electric interactive graphical scada system
schneider-electric interactive graphical scada system: no CVSS score yet. EPSS 21% estimated probability of exploitation activity in the next 30 days.
On this page
- EPSS
- 21% (unchanged from 21% a week ago; 21% 30 days ago) estimated probability of exploitation activity in the next 30 days; 98th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
- CWE
- CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer
- Published
- Modified
- NVD analysis
- Analyzed, since modified
- Record from
- the NVD, synced
Fix and patched versions
- Patch: http://igss.schneider-electric.com/igss/igssupdates/v100/progupdatesv100.zip
- Patch: http://igss.schneider-electric.com/igss/igssupdates/v90/progupdatesv90.zip
- Patch: http://www.us-cert.gov/control_systems/pdf/ICSA-13-018-01.pdf
Ask an AI about this CVE
Show the prompt
Explain CVE-2013-0657 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2013-0657?via=ask-ai-copy and https://cve.bz/cve/CVE-2013-0657?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2013-0657 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.
Affected
Versions
From the NVD's CPE matches.
| Product | Affected |
|---|---|
| schneider-electric:interactive_graphical_scada_system | through 10.0 |
| schneider-electric:interactive_graphical_scada_system | 9.0 |
ICS advisories (CISA)
| Advisory | Title | Published | Sectors | Affected | Fixed |
|---|---|---|---|---|---|
| ICSA-13-018-01 | Schneider Electric IGSS Buffer Overflow | 2013-10-22 | Schneider Electric IGSS application: vers:all/* | none listed |
From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.
Public exploits
- Exploit-DB SEIG SCADA System 9 - Remote Code Execution
- Exploit-DB 7-Technologies IGSS 9 - Data Server/Collector Packet Handling (Metasploit)
Detection rules
Ways to detect this CVE, not exploit code: the nuclei template that checks a system for it, and the Suricata and Snort rules that name it. A rule set may ship a rule turned off, so check yours by its sid.
- Emerging Threats Open ET SCADA SEIG SYSTEM 9 - Remote Code Execution sid 2026003
Attack patterns (CAPEC)
The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits. More on the page of CWE-119 (12).