Integer overflow in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage or RNADiagReceiver.exe daemon crash) via UDP data that specifies a large integer value.
EPSS
3.2% (unchanged from 3.2% a week ago; 3.2% 30 days ago) estimated probability of exploitation activity in the next 30 days; 89th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-189 Numeric Errors
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2012-4714 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2012-4714?via=ask-ai-copy and https://cve.bz/cve/CVE-2012-4714?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2012-4714 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
rockwellautomation:factorytalk_services_platformcpr9
rockwellautomation:factorytalk_services_platformcpr9:sr1
rockwellautomation:factorytalk_services_platformcpr9:sr2
rockwellautomation:factorytalk_services_platformcpr9:sr3
rockwellautomation:factorytalk_services_platformcpr9:sr4
rockwellautomation:factorytalk_services_platformcpr9:sr5
rockwellautomation:factorytalk_services_platformcpr9:sr5.1
rockwellautomation:factorytalk_services_platformcpr9:sr6

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-13-095-02ARockwell Automation FactoryTalk and RSLinx Vulnerabilities2013-01-07Rockwell Automation FactoryTalk Services Platform and RSLinx Enterprise: CPR9, Rockwell Automation FactoryTalk Services Platform and RSLinx Enterprise: CPR9-SR1, Rockwell Automation FactoryTalk Services Platform and RSLinx Enterprise: CPR9-SR2 and 5 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.