CVE-2012-4356 sielcosistemi: Path traversal
sielcosistemi: no CVSS score yet. EPSS 27% estimated probability of exploitation activity in the next 30 days.
On this page
Multiple directory traversal vulnerabilities in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 allow remote attackers to read arbitrary files via port-46824 TCP packets specifying a file-open operation with opcode 0x78 and a .. (dot dot) in a pathname, followed by a file-read operation with opcode (1) 0x96, (2) 0x97, or (3) 0x98.
- EPSS
- 27% (unchanged from 27% a week ago; 27% 30 days ago) estimated probability of exploitation activity in the next 30 days; 98th percentile. Scored 2026-11-23. A forecast for this CVE across the internet, not for your own systems.
- CWE
- CWE-22 Improper Limitation of a Pathname to a Restricted Directory (Path traversal)
- OWASP Top 10
- A01:2025 Broken Access Control
- Published
- Modified
- NVD analysis
- Analyzed, since modified
- Record from
- the NVD, synced
Fix and patched versions
- Vendor advisory: http://secunia.com/advisories/49395
Ask an AI about this CVE
Show the prompt
Explain CVE-2012-4356 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2012-4356?via=ask-ai-copy and https://cve.bz/cve/CVE-2012-4356?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2012-4356 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.
Affected
Versions
From the NVD's CPE matches.
| Product | Affected |
|---|---|
| sielcosistemi:winlog_pro | through 2.07.16 |
| sielcosistemi:winlog_pro | 2.06.00 |
| sielcosistemi:winlog_pro | 2.06.03 |
| sielcosistemi:winlog_pro | 2.06.04 |
| sielcosistemi:winlog_pro | 2.06.06 |
| sielcosistemi:winlog_pro | 2.06.09 |
| sielcosistemi:winlog_pro | 2.06.10 |
| sielcosistemi:winlog_pro | 2.06.12 |
| sielcosistemi:winlog_pro | 2.06.13 |
| sielcosistemi:winlog_pro | 2.06.14 |
| sielcosistemi:winlog_pro | 2.06.18 |
| sielcosistemi:winlog_pro | 2.06.21 |
| sielcosistemi:winlog_pro | 2.06.24 |
| sielcosistemi:winlog_pro | 2.06.25 |
| sielcosistemi:winlog_pro | 2.06.28 |
| sielcosistemi:winlog_pro | 2.06.40 |
| sielcosistemi:winlog_pro | 2.06.46 |
| sielcosistemi:winlog_pro | 2.06.50 |
| sielcosistemi:winlog_pro | 2.06.60 |
| sielcosistemi:winlog_pro | 2.06.73 |
| sielcosistemi:winlog_pro | 2.06.86 |
| sielcosistemi:winlog_pro | 2.07.00 |
| sielcosistemi:winlog_pro | 2.07.01 |
| sielcosistemi:winlog_pro | 2.07.08 |
| sielcosistemi:winlog_pro | 2.07.09 |
| sielcosistemi:winlog_pro | 2.07.11 |
| sielcosistemi:winlog_pro | 2.07.14 |
| sielcosistemi:winlog_lite | through 2.07.16 |
| sielcosistemi:winlog_lite | 2.06.00 |
| sielcosistemi:winlog_lite | 2.06.03 |
| sielcosistemi:winlog_lite | 2.06.04 |
| sielcosistemi:winlog_lite | 2.06.06 |
| sielcosistemi:winlog_lite | 2.06.09 |
| sielcosistemi:winlog_lite | 2.06.10 |
| sielcosistemi:winlog_lite | 2.06.12 |
| sielcosistemi:winlog_lite | 2.06.13 |
| sielcosistemi:winlog_lite | 2.06.14 |
| sielcosistemi:winlog_lite | 2.06.18 |
| sielcosistemi:winlog_lite | 2.06.21 |
| sielcosistemi:winlog_lite | 2.06.24 |
| sielcosistemi:winlog_lite | 2.06.25 |
| sielcosistemi:winlog_lite | 2.06.28 |
| sielcosistemi:winlog_lite | 2.06.40 |
| sielcosistemi:winlog_lite | 2.06.46 |
| sielcosistemi:winlog_lite | 2.06.50 |
| sielcosistemi:winlog_lite | 2.06.60 |
| sielcosistemi:winlog_lite | 2.06.73 |
| sielcosistemi:winlog_lite | 2.06.86 |
| sielcosistemi:winlog_lite | 2.07.00 |
| sielcosistemi:winlog_lite | 2.07.01 |
| sielcosistemi:winlog_lite | 2.07.08 |
| sielcosistemi:winlog_lite | 2.07.09 |
| sielcosistemi:winlog_lite | 2.07.11 |
| sielcosistemi:winlog_lite | 2.07.14 |
ICS advisories (CISA)
| Advisory | Title | Published | Sectors | Affected | Fixed |
|---|---|---|---|---|---|
| ICSA-12-213-01A | Sielco Sistemi Winlog Multiple Vulnerabilities | 2012-05-04 | Sielco Sistemi Winlog Pro SCADA: <2.07.18, Sielco Sistemi Winlog Lite SCADA: <2.07.18. | none listed |
From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.
Public exploits
- Exploit-DB Sielco Sistemi Winlog <= 2.07.16 - Multiple Vulnerabilities
- Metasploit Sielco Sistemi Winlog Remote File Access
Attack patterns (CAPEC)
- CAPEC-64 Using Slashes and URL Encoding Combined to Bypass Validation Logic Likelihood: High · Severity: High
- CAPEC-76 Manipulating Web Input to File System Calls Likelihood: High · Severity: Very High
- CAPEC-78 Using Escaped Slashes in Alternate Encoding Likelihood: High · Severity: High
- CAPEC-79 Using Slashes in Alternate Encoding Likelihood: High · Severity: High
- CAPEC-126 Path Traversal Likelihood: High · Severity: Very High
The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.