CVE-2012-3005 invensys
invensys: no CVSS score yet. EPSS 0.4% estimated probability of exploitation activity in the next 30 days.
Untrusted search path vulnerability in Invensys Wonderware InTouch 2012 and earlier, as used in Wonderware Application Server, Wonderware Information Server, Foxboro Control Software, InFusion CE/FE/SCADA, InBatch, and Wonderware Historian, allows local users to gain privileges via a Trojan horse DLL in an unspecified directory.
- EPSS
- 0.4% (unchanged from 0.4% a week ago; 0.4% 30 days ago) estimated probability of exploitation activity in the next 30 days; 31st percentile. Scored 2026-11-26. A forecast for this CVE across the internet, not for your own systems.
- Published
- Modified
- NVD analysis
- Analyzed, since modified
- Record from
- the NVD, synced
Ask an AI about this CVE
Show the prompt
Explain CVE-2012-3005 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2012-3005?via=ask-ai-copy and https://cve.bz/cve/CVE-2012-3005?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2012-3005 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.
Affected
- invensys:foxboro_control_software
- invensys:infusion_ce\/fe\/scada
- invensys:intouch
- invensys:intouch\/wonderware_application_server
- invensys:wonderware_historian
- invensys:wonderware_inbatch
- invensys:wonderware_information_server
Versions
From the NVD's CPE matches.
| Product | Affected |
|---|---|
| invensys:foxboro_control_software | 3.1 |
| invensys:foxboro_control_software | 4.0 |
| invensys:infusion_ce/fe/scada | through 2.5 |
| invensys:intouch | through 2012 |
| invensys:intouch/wonderware_application_server | through 2012 |
| invensys:intouch/wonderware_application_server | 10.0 |
| invensys:intouch/wonderware_application_server | 10.5 |
| invensys:wonderware_historian | through 10.0 |
| invensys:wonderware_historian | 10.0 |
| invensys:wonderware_inbatch | through 9.5 |
| invensys:wonderware_information_server | through 4.5 |
| invensys:wonderware_information_server | 3.1 |
| invensys:wonderware_information_server | 4.0 |
| invensys:wonderware_information_server | 4.0:sp1 |
ICS advisories (CISA)
| Advisory | Title | Published | Sectors | Affected | Fixed |
|---|---|---|---|---|---|
| ICSA-12-177-02 | Invensys Wonderware InTouch 10 DLL Hijack | 2012-03-29 | Invensys InTouch: <2012, Invensys Wonderware Application Server: <2012, Invensys Wonderware Information Server: <4.5 and 4 more | none listed |
From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.