CVE-2011-5163
No CVSS score yet. EPSS 0.5% estimated probability of exploitation activity in the next 30 days.
On this page
Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence.
- EPSS
- 0.5% (unchanged from 0.5% a week ago; 0.5% 30 days ago) estimated probability of exploitation activity in the next 30 days; 42nd percentile. Scored 2026-11-21. A forecast for this CVE across the internet, not for your own systems.
- CWE
- CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer
- Published
- Modified
- NVD analysis
- Analyzed, since modified
- Record from
- the NVD, synced
Fix and patched versions
- Vendor advisory: http://secunia.com/advisories/46779
- Vendor advisory: http://secunia.com/advisories/46786
Ask an AI about this CVE
Show the prompt
Explain CVE-2011-5163 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2011-5163?via=ask-ai-copy and https://cve.bz/cve/CVE-2011-5163?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2011-5163 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.
Affected
Versions
From the NVD's CPE matches.
| Product | Affected |
|---|---|
| mitsubishi-automation:mx4_scada | through 7.10 |
| schneider-electric:citectscada | through 7.10 |
ICS advisories (CISA)
| Advisory | Title | Published | Sectors | Affected | Fixed |
|---|---|---|---|---|---|
| ICSA-11-279-02 | CitectSCADA and Mitsubishi MX4 SCADA Batch Server Buffer Overflow | 2011-07-09 | Schneider Electric Schneider Electric CitectSCADA using the CitectSCADA Batch Server module: <=V7.10, Schneider Electric Mitsubishi MX4 SCADA using the MX4 SCADA Batch module: <=V7.10 | none listed |
From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.
Attack patterns (CAPEC)
The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits. More on the page of CWE-119 (12).
References
- http://secunia.com/advisories/46779
- http://secunia.com/advisories/46786
- http://www.citect.com/citectscada-batch
- http://www.osvdb.org/76937
- http://www.securitytracker.com/id?1026306
- http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf
- https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1&doc_type=safety&scat=2&sstr=MX4%2CSCADA