cve.bz

CVE-2011-4875 siemens

no score yetExploitEPSS 14%

siemens: no CVSS score yet. EPSS 14% estimated probability of exploitation activity in the next 30 days.

On this page
Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute arbitrary code via vectors related to Unicode strings.
EPSS
14% (unchanged from 14% a week ago; 14% 30 days ago) estimated probability of exploitation activity in the next 30 days; 97th percentile. Scored 2026-11-21. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2011-4875 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2011-4875?via=ask-ai-copy and https://cve.bz/cve/CVE-2011-4875?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2011-4875 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
siemens:wincc_flexible2004
siemens:wincc_flexible2005
siemens:wincc_flexible2007
siemens:wincc_flexible2008
siemens:winccv11
siemens:simatic_hmi_panelscomfort_panels
siemens:simatic_hmi_panelsmobile_panels
siemens:simatic_hmi_panelsmp
siemens:simatic_hmi_panelsop
siemens:simatic_hmi_panelstp
siemens:wincc_runtime_advancedv11

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-12-030-01ASiemens SIMATIC WinCC Vulnerabilities2012-11-02Siemens WinCC flexible: 2004|2005|2007|2008, Siemens WinCC V11 (TIA portal): vers:all/*, Siemens Multiple SIMATIC HMI panels (TP, OP, MP, Comfort Panels, Mobile Panels): vers:all/* and 2 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Public exploits

Attack patterns (CAPEC)

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits. More on the page of CWE-119 (12).

References

Check your stackJSON