CVE-2011-3489 rockwellautomation rslogix
rockwellautomation rslogix: no CVSS score yet. EPSS 8.7% estimated probability of exploitation activity in the next 30 days.
On this page
RnaUtility.dll in RsvcHost.exe 2.30.0.23 in Rockwell RSLogix 19 and earlier allows remote attackers to cause a denial of service (crash) via a crafted rna packet with a long string to TCP port 4446 that triggers (1) "a memset zero overflow" or (2) an out-of-bounds read, related to improper handling of a 32-bit size field.
- EPSS
- 8.7% (unchanged from 8.7% a week ago; 8.7% 30 days ago) estimated probability of exploitation activity in the next 30 days; 95th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
- CWE
- CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer
- Published
- Modified
- NVD analysis
- Analyzed, since modified
- Record from
- the NVD, synced
Ask an AI about this CVE
Show the prompt
Explain CVE-2011-3489 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2011-3489?via=ask-ai-copy and https://cve.bz/cve/CVE-2011-3489?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2011-3489 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.
Affected
Versions
From the NVD's CPE matches.
| Product | Affected |
|---|---|
| rockwellautomation:rslogix | through 19 |
ICS advisories (CISA)
| Advisory | Title | Published | Sectors | Affected | Fixed |
|---|---|---|---|---|---|
| ICSA-11-273-03A | Rockwell RSLogix Overflow Vulnerability | 2011-07-03 | Rockwell Automation RSLogix 5000 software: 17|18|19, Rockwell Automation All FactoryTalk-branded software of specific: CPR9, Rockwell Automation All FactoryTalk-branded software of specific: >=CPR9-SR1|<=CPR9-SR4 | none listed |
From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.
Public exploits
- Exploit-DB Rockwell RSLogix 19 - Denial of Service
Detection rules
Ways to detect this CVE, not exploit code: the nuclei template that checks a system for it, and the Suricata and Snort rules that name it. A rule set may ship a rule turned off, so check yours by its sid.
- Emerging Threats Open ET SCADA Rockwell RNA Message Large Header Length - 8Kb sid 2049795
Attack patterns (CAPEC)
The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits. More on the page of CWE-119 (12).