{"cve":"CVE-2026-94142","nvd":{"published":"2026-09-21T05:16:42.053","modified":"2026-09-21T20:17:40.953","status":"Deferred","description":"A security vulnerability has been detected in BioStar Temperature Monitor Utility 1.2.1806.2200. Affected by this vulnerability is the function sub_1105C of the file BS_HWMIO64_W10.sys of the component IOCTL Handler. Such manipulation of the argument PhysicalAddress leads to write-what-where condition. The attack needs to be performed locally. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.","cvss_v4":{"vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P","score":8.5},"cvss_v3":{"version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","score":8.8},"cwes":["CWE-119","CWE-123"],"references":["https://vuldb.com/cve/CVE-2026-94142","https://vuldb.com/submit/893919","https://vuldb.com/vuln/408057","https://vuldb.com/vuln/408057/cti","https://vuldb.com/submit/893919"],"products":[],"source":"nvd","synced_at":"2026-10-19T22:55:23.253742848+00:00"},"epss":{"cve":"CVE-2026-94142","score":0.00182,"percentile":0.07777,"date":"2026-10-31"},"kev":null,"osv":[],"attribution":["This product uses the NVD API but is not endorsed or certified by the NVD.","EPSS scores: FIRST Exploit Prediction Scoring System, https://www.first.org/epss","Known exploited vulnerabilities: CISA Known Exploited Vulnerabilities Catalog, https://www.cisa.gov/known-exploited-vulnerabilities-catalog","Package advisories: OSV (https://osv.dev), from the GitHub Advisory Database, PyPA, Go, RustSec and other ecosystem databases, under CC-BY 4.0 or CC0","CVE records: the CVE Program's CVE List (https://www.cve.org), under its terms of use (https://www.cve.org/Legal/TermsOfUse). CVE is a registered trademark of The MITRE Corporation; this product is not affiliated with the CVE Program."]}