{"cve":"CVE-2025-22051","nvd":{"published":"2025-04-16T15:15:58.547","modified":"2026-06-17T08:44:56.010","status":"Modified","description":"In the Linux kernel, the following vulnerability has been resolved:\n\nstaging: gpib: Fix Oops after disconnect in agilent usb\n\nIf the agilent usb dongle is disconnected subsequent calls to the\ndriver cause a NULL dereference Oops as the bus_interface\nis set to NULL on disconnect.\n\nThis problem was introduced by setting usb_dev from the bus_interface\nfor dev_xxx messages.\n\nPreviously bus_interface was checked for NULL only in the functions\ndirectly calling usb_fill_bulk_urb or usb_control_msg.\n\nCheck for valid bus_interface on all interface entry points\nand return -ENODEV if it is NULL.","cvss_v4":null,"cvss_v3":{"version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","score":5.5},"cwes":["CWE-476"],"references":["https://git.kernel.org/stable/c/50ef6e45bec79da4c5a01fad4dc23466ba255099","https://git.kernel.org/stable/c/8491e73a5223acb0a4b4d78c3f8b96aa9c5e774d","https://git.kernel.org/stable/c/e88633705078f40391a9afc6cc8ea3025e6f692b"],"products":["linux:linux_kernel"],"source":"nvd","synced_at":"2026-10-19T22:01:11.054312287+00:00"},"epss":{"cve":"CVE-2025-22051","score":0.00199,"percentile":0.09764,"date":"2026-10-31"},"kev":null,"osv":[],"attribution":["This product uses the NVD API but is not endorsed or certified by the NVD.","EPSS scores: FIRST Exploit Prediction Scoring System, https://www.first.org/epss","Known exploited vulnerabilities: CISA Known Exploited Vulnerabilities Catalog, https://www.cisa.gov/known-exploited-vulnerabilities-catalog","Package advisories: OSV (https://osv.dev), from the GitHub Advisory Database, PyPA, Go, RustSec and other ecosystem databases, under CC-BY 4.0 or CC0","CVE records: the CVE Program's CVE List (https://www.cve.org), under its terms of use (https://www.cve.org/Legal/TermsOfUse). CVE is a registered trademark of The MITRE Corporation; this product is not affiliated with the CVE Program."]}