{"cve":"CVE-2023-44320","nvd":{"published":"2023-11-14T11:15:12.757","modified":"2026-06-17T06:27:23.580","status":"Modified","description":"A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V7.2.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V7.2.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V7.2.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V7.2.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V7.2.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V7.2.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V7.2.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V7.2.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V7.2.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V7.2.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V7.2.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V7.2.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V7.2.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V7.2.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V7.2.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V7.2.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V7.2.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V7.2.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V7.2.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V7.2.2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected devices do not properly validate the authentication when performing certain modifications in the web interface allowing an authenticated attacker to influence the user interface configured by an administrator.","cvss_v4":null,"cvss_v3":{"version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N","score":4.3},"cwes":["CWE-425"],"references":["https://cert-portal.siemens.com/productcert/html/ssa-068047.html","https://cert-portal.siemens.com/productcert/html/ssa-180704.html","https://cert-portal.siemens.com/productcert/html/ssa-602936.html","https://cert-portal.siemens.com/productcert/html/ssa-699386.html","https://cert-portal.siemens.com/productcert/html/ssa-769027.html"],"products":["siemens:6ag1206-2bb00-7ac2_firmware","siemens:6ag1206-2bs00-7ac2_firmware","siemens:6ag1208-0ba00-7ac2_firmware","siemens:6ag1216-4bs00-7ac2_firmware","siemens:6gk5204-0ba00-2gf2_firmware","siemens:6gk5204-0ba00-2yf2_firmware","siemens:6gk5204-2aa00-2gf2_firmware","siemens:6gk5204-2aa00-2yf2_firmware","siemens:6gk5205-3bb00-2ab2_firmware","siemens:6gk5205-3bb00-2tb2_firmware","siemens:6gk5205-3bd00-2ab2_firmware","siemens:6gk5205-3bd00-2tb2_firmware","siemens:6gk5205-3bf00-2ab2_firmware","siemens:6gk5205-3bf00-2tb2_firmware","siemens:6gk5206-2bb00-2ac2_firmware","siemens:6gk5206-2bd00-2ac2_firmware","siemens:6gk5206-2bs00-2ac2_firmware","siemens:6gk5206-2bs00-2fc2_firmware","siemens:6gk5206-2gs00-2ac2_firmware","siemens:6gk5206-2gs00-2fc2_firmware","siemens:6gk5206-2gs00-2tc2_firmware","siemens:6gk5206-2rs00-2ac2_firmware","siemens:6gk5206-2rs00-5ac2_firmware","siemens:6gk5206-2rs00-5fc2_firmware","siemens:6gk5208-0ba00-2ab2_firmware","siemens:6gk5208-0ba00-2ac2_firmware","siemens:6gk5208-0ba00-2fc2_firmware","siemens:6gk5208-0ba00-2tb2_firmware","siemens:6gk5208-0ga00-2ac2_firmware","siemens:6gk5208-0ga00-2fc2_firmware","siemens:6gk5208-0ga00-2tc2_firmware","siemens:6gk5208-0ha00-2as6_firmware","siemens:6gk5208-0ha00-2es6_firmware","siemens:6gk5208-0ha00-2ts6_firmware","siemens:6gk5208-0ra00-2ac2_firmware","siemens:6gk5208-0ra00-5ac2_firmware","siemens:6gk5208-0ua00-5es6_firmware","siemens:6gk5213-3bb00-2ab2_firmware","siemens:6gk5213-3bb00-2tb2_firmware","siemens:6gk5213-3bd00-2ab2_firmware","siemens:6gk5213-3bd00-2tb2_firmware","siemens:6gk5213-3bf00-2ab2_firmware","siemens:6gk5213-3bf00-2tb2_firmware","siemens:6gk5216-0ba00-2ab2_firmware","siemens:6gk5216-0ba00-2ac2_firmware","siemens:6gk5216-0ba00-2fc2_firmware","siemens:6gk5216-0ba00-2tb2_firmware","siemens:6gk5216-0ha00-2as6_firmware","siemens:6gk5216-0ha00-2es6_firmware","siemens:6gk5216-0ha00-2ts6_firmware"],"source":"nvd","synced_at":"2026-10-19T21:42:07.670898610+00:00"},"epss":{"cve":"CVE-2023-44320","score":0.00643,"percentile":0.50814,"date":"2026-10-31"},"kev":null,"osv":[],"attribution":["This product uses the NVD API but is not endorsed or certified by the NVD.","EPSS scores: FIRST Exploit Prediction Scoring System, https://www.first.org/epss","Known exploited vulnerabilities: CISA Known Exploited Vulnerabilities Catalog, https://www.cisa.gov/known-exploited-vulnerabilities-catalog","Package advisories: OSV (https://osv.dev), from the GitHub Advisory Database, PyPA, Go, RustSec and other ecosystem databases, under CC-BY 4.0 or CC0","CVE records: the CVE Program's CVE List (https://www.cve.org), under its terms of use (https://www.cve.org/Legal/TermsOfUse). CVE is a registered trademark of The MITRE Corporation; this product is not affiliated with the CVE Program."]}