{"cve":"CVE-2019-10928","nvd":{"published":"2019-08-13T19:15:14.767","modified":"2026-06-17T02:11:55.650","status":"Modified","description":"A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device.","cvss_v4":null,"cvss_v3":{"version":"3.1","vector":"CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","score":6.6},"cwes":["CWE-703"],"references":["https://cert-portal.siemens.com/productcert/pdf/ssa-671286.pdf","https://cert-portal.siemens.com/productcert/pdf/ssa-671286.pdf"],"products":["siemens:scalance_sc-600_firmware"],"source":"nvd","synced_at":"2026-10-19T20:58:11.797917892+00:00"},"epss":{"cve":"CVE-2019-10928","score":0.00408,"percentile":0.3508,"date":"2026-10-31"},"kev":null,"osv":[],"attribution":["This product uses the NVD API but is not endorsed or certified by the NVD.","EPSS scores: FIRST Exploit Prediction Scoring System, https://www.first.org/epss","Known exploited vulnerabilities: CISA Known Exploited Vulnerabilities Catalog, https://www.cisa.gov/known-exploited-vulnerabilities-catalog","Package advisories: OSV (https://osv.dev), from the GitHub Advisory Database, PyPA, Go, RustSec and other ecosystem databases, under CC-BY 4.0 or CC0","CVE records: the CVE Program's CVE List (https://www.cve.org), under its terms of use (https://www.cve.org/Legal/TermsOfUse). CVE is a registered trademark of The MITRE Corporation; this product is not affiliated with the CVE Program."]}