{"cve":"CVE-2015-1014","nvd":{"published":"2019-03-25T19:29:00.337","modified":"2026-06-17T00:21:38.587","status":"Modified","description":"A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version.","cvss_v4":null,"cvss_v3":{"version":"3.0","vector":"CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","score":7.3},"cwes":["CWE-427"],"references":["https://ics-cert.us-cert.gov/advisories/ICSA-15-141-01","https://ics-cert.us-cert.gov/advisories/ICSA-15-141-01"],"products":["schneider-electric:opc_factory_server"],"source":"nvd","synced_at":"2026-10-19T20:55:22.313337056+00:00"},"epss":{"cve":"CVE-2015-1014","score":0.00456,"percentile":0.39554,"date":"2026-10-31"},"kev":null,"osv":[],"attribution":["This product uses the NVD API but is not endorsed or certified by the NVD.","EPSS scores: FIRST Exploit Prediction Scoring System, https://www.first.org/epss","Known exploited vulnerabilities: CISA Known Exploited Vulnerabilities Catalog, https://www.cisa.gov/known-exploited-vulnerabilities-catalog","Package advisories: OSV (https://osv.dev), from the GitHub Advisory Database, PyPA, Go, RustSec and other ecosystem databases, under CC-BY 4.0 or CC0","CVE records: the CVE Program's CVE List (https://www.cve.org), under its terms of use (https://www.cve.org/Legal/TermsOfUse). CVE is a registered trademark of The MITRE Corporation; this product is not affiliated with the CVE Program."]}