{"cve":"CVE-2014-0774","nvd":{"published":"2014-02-28T06:18:54.277","modified":"2026-06-17T00:03:37.120","status":"Modified","description":"Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file.","cvss_v4":null,"cvss_v3":null,"cwes":["CWE-121","CWE-119"],"references":["http://www.securityfocus.com/bid/65871","https://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-031-01","https://www.cisa.gov/news-events/ics-advisories/icsa-14-058-02","http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-031-01","http://ics-cert.us-cert.gov/advisories/ICSA-14-058-02"],"products":["schneider-electric:ofs_test_client_tlxcdlfofs33","schneider-electric:ofs_test_client_tlxcdltofs33","schneider-electric:ofs_test_client_tlxcdluofs33","schneider-electric:ofs_test_client_tlxcdstofs33","schneider-electric:ofs_test_client_tlxcdsuofs33","schneider-electric:opc_factory_server"],"source":"nvd","synced_at":"2026-10-19T20:32:06.812358378+00:00"},"epss":{"cve":"CVE-2014-0774","score":0.00467,"percentile":0.40486,"date":"2026-10-31"},"kev":null,"osv":[],"attribution":["This product uses the NVD API but is not endorsed or certified by the NVD.","EPSS scores: FIRST Exploit Prediction Scoring System, https://www.first.org/epss","Known exploited vulnerabilities: CISA Known Exploited Vulnerabilities Catalog, https://www.cisa.gov/known-exploited-vulnerabilities-catalog","Package advisories: OSV (https://osv.dev), from the GitHub Advisory Database, PyPA, Go, RustSec and other ecosystem databases, under CC-BY 4.0 or CC0","CVE records: the CVE Program's CVE List (https://www.cve.org), under its terms of use (https://www.cve.org/Legal/TermsOfUse). CVE is a registered trademark of The MITRE Corporation; this product is not affiliated with the CVE Program."]}