{"cve":"CVE-2012-1800","nvd":{"published":"2012-04-18T10:33:34.933","modified":"2026-06-16T23:40:19.763","status":"Modified","description":"Stack-based buffer overflow in the Profinet DCP protocol implementation on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 allows remote attackers to cause a denial of service (device outage) or possibly execute arbitrary code via a crafted DCP frame.","cvss_v4":null,"cvss_v3":null,"cwes":["CWE-119"],"references":["http://osvdb.org/81034","http://support.automation.siemens.com/WW/view/en/59869684","http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-268149.pdf","http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-05.pdf","http://osvdb.org/81034"],"products":["siemens:scalance_s602","siemens:scalance_s612","siemens:scalance_s613","siemens:scalance_s_firmware"],"source":"nvd","synced_at":"2026-10-19T20:24:00.973572543+00:00"},"epss":{"cve":"CVE-2012-1800","score":0.01598,"percentile":0.75769,"date":"2026-10-31"},"kev":null,"osv":[],"attribution":["This product uses the NVD API but is not endorsed or certified by the NVD.","EPSS scores: FIRST Exploit Prediction Scoring System, https://www.first.org/epss","Known exploited vulnerabilities: CISA Known Exploited Vulnerabilities Catalog, https://www.cisa.gov/known-exploited-vulnerabilities-catalog","Package advisories: OSV (https://osv.dev), from the GitHub Advisory Database, PyPA, Go, RustSec and other ecosystem databases, under CC-BY 4.0 or CC0","CVE records: the CVE Program's CVE List (https://www.cve.org), under its terms of use (https://www.cve.org/Legal/TermsOfUse). CVE is a registered trademark of The MITRE Corporation; this product is not affiliated with the CVE Program."]}